Abstract
Objectives: Build, with 3D technology, a customized biomechanical orthosis for elbow injuries caused by ischemic stroke and establish a cost-effectiveness relationship between its efficiency and production value. Method: This research is characterized by being quantitative, descriptive, analytical and cross-sectional. The sample consisted of 8 patients, 3 males and 5 females, who had a diagnosis of Ischemic Stroke. The instrument used to obtain the orthoses models was the Ultimaker 2+ machine and the Medical Research Council (MRC) Score. for the evaluation of the research components. Results: It was noticeable the evolution of muscle strength gain between individuals before and after the use of the orthosis. Conclusion: The personalized and customizable dynamic assistance orthosis, through the 3D printing technique, favored muscle strength gain and facilitated adjustments according to the patient's need, being considered as another promising health technology to assist in the rehabilitation process.
References
ANDERLE P, et al. Reabilitação pós-AVC: identificação de sinais e sintomas fonoaudiológicos por enfermeiros e médicos da Atenção Primária à Saúde. In: CoDAS. Sociedade Brasileira de Fonoaudiologia, 2019; 31(2).
ARAÚJO JP, et al. Tendência da mortalidade por acidente vascular cerebral no Município de Maringá, Paraná entre os anos de 2005 a 2015. International Journal of Cardiovascular Sciences, 2018; 31: 56-62.
BERSCH R. Introdução à tecnologia assistiva. 2017. http://www.assistiva.com.br/Introducao_Tecnologia_Assistiva.pdf. Acesso em: 10 Setembro 2022.
BRANDÃO, MB, et al. Uso da mão de assistência eo desempenho bimanual no autocuidado de crianças com paralisia cerebral unilateral espástica. Developmental Medicine & Child Neurology, 2023; 65(3): e1-e8.
BRASIL. Ministério da Saúde. Acidente Vascular Cerebral – AVC. 2021 Disponível em: https://bvsms.saude.gov.br/avc-acidente-vascular-cerebral/. Acesso em: 12 Outubro 2021.
BRASIL. Ministério da Saúde. Diretrizes de Atenção à reabilitação da pessoa com Acidente Vascular Cerebral. Ministério da Saúde: Brasília, 2013; 1: 72.
BRASIL. Subsecretaria Nacional de Promoção dos Direitos da Pessoa com Deficiência. Comitê de Ajudas Técnicas. Tecnologia Assistiva; CORDE: Brasília, 2009; 138.
DE JONGHE B, et al. Respiratory weakness is associated with limb weakness and delayed weaning in critical illness. Critical Care Medicine, 2007; 35: 2007-2015.
GOLSHANI K, et al. Upper Extremity Weightlifting Injuries: diagnosis and management. Journal of Orthopaedics, 2018; 15(1): 24-27.
GRADIM LCC e PAIVA G. Modelos de órteses para membros superiores: uma revisão da literatura. Cadernos Brasileiros de Terapia Ocupacional, 2018; 26: 479-88.
International Organization for Standardization 9999. Assistive products for persons with disability: classification and terminology. Genebra, Suíça: International Organization for Standardization. 2016; 6: 19.
INSTITUTO BRASILEIRO DE GEOGRAFIA E ESTATÍSTICA (IBGE). Pesquisa nacional de saúde: 2013: percepção do estado de saúde, estilo de vida e doenças crônicas: Brasil, grandes regiões e unidades federação. IBGE, Coordenação de trabalho e rendimento; IBGE: Rio de Janeiro, 2014; 91110.
KUMAR N, et al. The effect of process parameters on tensile behavior of 3D printed flexible parts of ethylene vinyl acetate (EVA). Journal of Manufacturing Processes, 2018; 35: 317-26.
MARINHO FD, et al. Uso de órtese impressa em 3D e tratamento terapêutico ocupacional na rizartrose. Cadernos Brasileiros de Terapia Ocupacional, 2020; 28: 1151-1164.
MORIMOTO SYU, et al. Órteses e próteses de membro superior impressas em 3D: uma revisão integrativa. Cadernos Brasileiros de Terapia Ocupacional, 2021; 29: 1-14.
NETO AS. Filamentos para impressão 3D: o que você precisa saber. 2016. Disponível em: https://www.wishbox.net.br/blog/filamentos-para-impressao-3d/. Acesso em: 20 Agosto 2022.
PARRY SM, et al. A new twotier strength assessment approach to the diagnosis of weakness in intensive care: an observational study. Critical Care, 2015; 19: 1-10.
RAJKUMARI K, et al. Three-Dimensional PrintingA Revolutionary Technology. Journal of Clinical and Diagnostic Research, 2018; 12: 12-18.
RIBAK S, et al. Epidemiology of Traumatic Injuries of the Upper Limbs in a University Hospital. Acta Ortopédica Brasileira, 2018; 26(6): 370-373.
ROMAN NA, et al. Customized Manual Muscle Testing for Post-Stroke Upper Extremity Assessment. Brain Science, 2022; 12: 1-18.
SANTOS JUNIOR J, et al. Associação do polimorfismo do gene CHGA em pacientes com acidente vascular encefálico hemorrágico e/ou aneurisma. Jornal Brasileiro de Patologia e Medicina Laboratorial, 2020; 56: 1-6.
SILVA SR, et al. Avaliação do membro superior pós-acidente vascular encefálico: correlação das escalas Motor Activity Log, Fugl-Meyer e Medida de Independência Funcional. Fisioterapia Brasil, 2017; 18: 734-42.
SILVEIRA AT, et al. From the past to the future of therapeutic orthoses for upper limbs rehabilitation. Research on Biomedical Engineering, 2017; 34: 368-80.
SMITH RO, et al. Assistive technology products: a position paper from the firt global research, innovation, and education on assistive technology (GREAT) summit. Disability and Rehabilitation: Assistive Technology, 2018; 13: 473-85.
TANLAKA E, et al. Inpatient Rehabilitation Care in Alberta: How Much Does Stroke Severity and Timing Matter?. Canadian Journal of Neurological Sciences, 2019; 46: 691-701.
THE HONG KONG POLYTECHNIC UNIVERSITY747. Motor Recovery of the Severely Impaired Paretic Upper Limb after Mirror Therapy in Sub-Acute Stroke; The Hong Kong Polytechnic University: Hong Kong, China, 2017; 140.
VARGAS IMP e RODRIGUES LP. Correlação entre espasticidade do membro superior e movimentação da mão no pós-AVC. Fisioterapia e Pesquisa, 2022; 29: 29-36.
VIANA FP, et al. Medida de independência funcional nas atividades de vida diária em idosos com seqüelas de acidente vascular encefálico no Complexo Gerontológico Sagrada Família de Goiânia. Revista Brasileira de Geriatria e Gerontologia, 2019; 11: 17-28.
WANG P, et al. Effects of printing parameters of fused deposition modeling on mechanical properties, surface quality, and microstructure of PEEK, Journal of Materials Processing Technology, 2019; 271: 62-74.
WORLD HEALTH ORGANIZATION. Global perspectives on assistive technology: Proceedings of the GReAT Consulation 2019. Geneva: World Health Organization, 2019; 2: 540.
WORLD HEALTH ORGANIZATION. Global perspectives on assistive technology: Proceedings of the GReAT Consultation 2019. World HealthOrganization: Geneva, 2019; 2: 570.
ZADPOOR A e MALDA J. Additive Manufacturing of Biomaterials, Tissues, and Organ. Annals of Biomedical Engineering, 2017; 45: 1-11.
ZUNIGA J, et al. Cyborg beast: a low cost 3D-printed prosthetic hand for children with upper- limb diferences. BMC Reserch Notes, 2015; 10(8): 1-8.